<LOGO>
FM Transmitter Measurement Report
Created: 2024-03-06 03-34-46
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 42 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
6 kHz 8 kHz 18994 0,0684
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,5 dBr -0,92 dBr 0,3 dBr 1,2
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 3:34, 6.03.2024
RT
"Pro a proti - Meli by majitele lesu dostat pravo je kvuli och..."
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 8 kHz MIN: 6 kHz % above 77 kHz: 0,0684 Acquired: 2024/03/06 3:34:43 Total samples: 18994 Equivalent time: 0:15:49 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 0,3 dBr MIN: -1,5 dBr AVE: -0,92 dBr % above 0,2 dBr: 1,2 Last value: -0,7 dBr (2024/03/06 3:34:43) 03:20 03:22 03:24 03:26 03:28 03:30 03:32 03:34 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality